this article mainly introduces the dismantling of the doosanDX340LC crawler excavator cabin
Doosan Diagnostic Tool UVIM Support Doosan Excavators High Quality
DoosanDX340LC
CAUTION!
Avoid disassembling cabin if there are strong wind gusts,
which could catch large surface area of cabin shell and
push it sideways during lift.
1. Park on firm and level ground.
2. Lower front attachment (bucket) to ground.
3. Shut down engine.
4. Set safety lever on "RELEASED" position.
5. Turn starter switch to "I" (ON) position.
WARNING!
If
engine must be run while performing maintenance, use extreme care.
Always have one person in the cabin at all times. Never leave the cabin
with the engine running.
6. Fully stroke work levers (joysticks) in all directions to
relieve pressure from accumulators.
7. Set safety lever on "LOCK" position.
8. Turn key to "O" (OFF) position and remove from starter
switch.
9. Hang maintenance warning tag on controls.
10. Disconnect the battery cable from the negative (-) battery
terminal.
11. Prepare cabin shell for removal by disconnecting wiring
connectors for:
A. Cabin interior lighting.
B. External light wiring.
C. Radio antenna and connections.
D. Wiper/washer connections.
NOTE: Control console wiring harnesses and hydraulic
piping lines that pass through the floor of the
cabin do not need to be disassembled.
NOTE: If unit is equipped with a cabin protective
structure (for forestry, or hazardous working
conditions), it must be removed
2023.07 Doosan DMS-5 Data Monitoring System Diagnostic Software
12. Remove floor mat.
13. Remove operator's seat (1, Figure 2).
NOTE: Be careful not to damage seat covering.
14. Remove duct covers (2, 3 and 4, Figure 2).
When removing cover (2) disconnect hour meter connector and cigar
lighter connector. Disconnect main harness connector before
removing cover (4).
15. Remove pocket (5, Figure 2) before removing side panel (6, Figure 2).
16. Remove air duct (1, 2 and 3, Figure 3) at right side of
cabin. Disconnect duct wiring connector before removing
duct (2).
17. Disconnect washer hose at floor plate bottom.
Doosan Diagnostic Tool DDT G2 SCAN( ECU ,DCU)Software 2016